The picture above shows the plan view of a gable roof ladder trusses are made up using four noggins bridging at each corner to support a rafter outside the building.
Gable roof load transfer.
Also the roof sheathing working in conjunction with the roof framing must function as a diaphragm to transfer lateral loads to the building s shear walls.
Three types of load apply to a gable roof.
15 psf x 14ft 210 pounds per lineal foot.
The roof framing must be able to bear the dead load plus the maximum anticipated live load and adequately transfer that load downward through the structure to the ground.
That rafter outside forms the overhang for the barge boards to fix to and so the soffit boards and ventilation are continuous all the way.
Live loads and.
In order for a structure to be sound and secure the foundation roof and walls must be strong and wind resistant.
No hips or valley s.
For example a gable end truss may be designed with support members that transmit the roof weight load outward to the side walls allowing the end wall directly below it to have breaks or openings in it that would otherwise be impossible.
Gable roof a gable roof is when all rafters extend downward from the ridge board beam.
Manufactured gable ends are actually frames even though they are often referred to as trusses.
Created by wind pressures.
The webs are studs oriented vertically and usually spaced at 12 16 or 24 in.
Then you can ensure adequate bearing points or add framing and install beams to carry the loads through the walls down to the foundation.
Soffit is the underside of a roof balcony or over hang.
It wouldn t be a bad idea to consult a structural engineer for guidance especially on larger dormers.
Loads affect the bracing roof covering.
Framing a gable roof building a gable with barge end purlin struts and collar ties.
Engineered roof truss systems may be designed to eliminate the need for load bearing walls or change where the bearing walls are located.
Whenever adding any type of dormer it s essential to determine the roof load and design the load path transfer to the existing floor joists or roof rafters.
Add together all live loads and dead loads that act on the member and then choose a material that will resist the load.
They transfer loads from above to the foundation below through a network of structural elements.
Dead live and wind.
When building a structure it is important to calculate wind load to ensure that the structure can withstand high winds especially if the building is located in an area known for inclement weather.
Hip roof a hip is a type of roof where all sides slope downward to the walls.
Another default roof in archicad.
The gable end frame is designed to transfer vertical loads from the roof to the continuous bearing wall below.
The idea behind sizing headers and beams is straight forward.